Interior of a crossflow truck paint booth, wide view toward the filter doors with side lighting and a filter wall along the left

TRUCK & FLEET

Crossflow Truck Booths for Semis, Buses and Fleets

PFS TRUCK BOOTHS

Built by Platinum Finishing Systems (PFS). Air travels the length of the booth from filtered doors to a rear exhaust wall — the most cost-effective way to paint semis, buses and fleet vehicles. ETL listed (Intertek) for the USA and Canada, NFPA 33 compliant, made in the USA. Ships nationally.

Trusted By Industry Leaders
  • Boeing
  • Ashley Furniture
  • SpaceX
  • Tesla
  • CAT
  • Carstar
  • Metro
  • AV
  • Seneca
  • LeROI
  • DG
  • G&C
  • Mission Bell
  • United Rentals
  • AEL
  • Google
PFS Orion crossflow truck paint booth filtered doors, three-quarter angle
FEATURED PAINT BOOTH

PFS Orion Crossflow Truck Booth

PFS TRUCK BOOTHS

Air moves the length of the booth from filtered doors to a rear exhaust wall. It sits on your existing slab — no pit — and a drive-through layout is available. Optional natural gas or electric heat, an air make-up unit, and spray and bake (cure) can be added.

  • No pit, sits on your slab
  • Lowest installed cost of the truck airflow options
  • Drive-through option
  • CID2 lighting and UL 508A control panel
  • Fiberglass exhaust and tacky intake filters
  • ETL listed (Intertek) for the USA and Canada, built to NFPA 33, made in the USA
Booth Details

Configurations, Airflow, Specs, Typical Sizes & Compliance

AVAILABLE CONFIGURATIONS

A pit-free truck booth, sized to your vehicles.

Crossflow truck booth airflow: filtered air enters through the front doors, travels horizontally the length of the booth and exits through exhaust filters in the rear wall to the exhaust stack

Crossflow

Air enters through intake filters in the front doors and exits through exhaust filters in the rear wall. That horizontal, front-to-rear path keeps overspray moving away from the painter, with no pit and a drive-through option.
Heated crossflow truck booth airflow: the air make-up unit feeds the front bridge plenum, air travels the length of the booth and exits through the rear bridge plenum on a drive-through booth, or a filtered back wall when it is not drive-through

Heated crossflow

Built with bridge plenums on both ends. Supply air from one or more PFS air make-up units enters through the front bridge plenum and exits through the rear bridge plenum on a drive-through booth, or through a filtered back wall if the booth is not drive-through. Gas-fired or electric heat, with spray, flash and cure modes on the PFS Core Control Panel. Humidity control is available on the AMU.
STANDARD SPECIFICATION

Certified. Engineered. Delivered Complete.

01

Industrial Service Lighting

Inside-access, Class I Division 2 (CID2) four-tube fixtures are standard. Fluorescent or LED tube compatible — optional LED upgrade available. manufactured in the USA with ETL/UL listed components. Uniform, shadow-free illumination.
02

UL-Listed Tube Axial Fans

Non-sparking tube-axial exhaust fans with belt guards and duct connector rings. UL/CUL and CSA recognized — three-phase, TEFC, tri-voltage — rated for continuous industrial duty.
03

Galvanized or Powder Coated Steel

18-gauge G90 galvanized sheet steel is standard. Powder coat finish available for environments requiring additional corrosion resistance. Structural steel columns and beams support horizontal panel assembly.
04

Exhaust & Intake Filtration

Fiberglass exhaust filters are standard. Intake uses tacky-type media — blanket intake upgrades available for heated booth configurations. Filtration matched to your process and NFPA 33 compliant.
05

PFS Core Control Panel

Non-pressurized booths ship with an electromechanical panel controlling exhaust, safety interlocks, and lighting. Pressurized configurations include spray, flash, and cure modes with programmable alarms.
TYPICAL SIZES

Common Booth Sizes (W × H × L)

Enclosed paint booths (W × H × L)

  • 14′ W × 9′ H × 24′, 27′, 30′ or 33′ L
  • 14′ W × 10′ H × 24′, 27′, 30′ or 33′ L
  • 14′ W × 12′ H × 24′, 27′, 30′ or 33′ L

Outdoor and large-format booths (W × H × L)

  • 14′ W × 9′ H × 24′, 27′ or 30′ L
  • 14′ W × 12′ H × 30′ L
  • 20′ W × 14′ H × 40′ L
  • 24′ W × 16′ H × 50′ L
  • 30′ W × 18′ H × 60′ L

Truck and fleet booths

  • Semi-truck: at least 16 ft wide × 50 ft deep × 14 ft tall
  • Cab and trailer together: 16–18 ft wide × 60–80 ft deep
  • Transit, school, and motor coaches: 14–16 ft wide × 40–60 ft deep × 12–14 ft tall
CODES & LISTINGS

Listed, Certified and Built to Code

PFS paint and spray booths are ETL listed by Intertek for flammable and combustible applications in the USA and Canada (cETLus). Control panels are UL 508A, including hazardous-location panels. Booths are built to NFPA 33, the IBC, and the NEC. Fire protection is dry chemical (Amerex, Pyro-Chem, or Stat-X) or sprinklers. PFS builds its own air make-up units.

  • Largest workpiece dimensions and production requirements
  • Airflow: cross-flow, side downdraft, downdraft, or semi-downdraft
  • Whether the booth needs integrated heat for an accelerated cure

Built for

Who a crossflow truck booth is for

Semi-trucks (Class 8 tractors)

A semi truck paint booth in this style starts at 16 ft W × 50 ft L × 14 ft H, with longer booths when the tractor and trailer stay together.

Transit, school and motor coaches

Typical working size is 14–16 ft W × 40–60 ft L × 12–14 ft H, with drive-through when you want a straight path through the shop.

Fleet vehicles, RVs and larger equipment

Built to 20 × 14 × 40, 24 × 16 × 50, 30 × 18 × 60 ft and beyond when the job calls for it. A crossflow layout is the usual choice when installed cost matters.

SIZES

Typical sizes for trucks, buses and fleets

Typical truck and large-vehicle booth sizes (from the PFS truck and fleet hub)
ApplicationTypical working size
Class 8 tractor (semi-truck)At least 16 ft W × 50 ft L × 14 ft H
Tractor and trailer together16–18 ft W × 60–80 ft L
Transit, school and motor coaches14–16 ft W × 40–60 ft L × 12–14 ft H
Larger equipment and custom builds20 × 14 × 40, 24 × 16 × 50, 30 × 18 × 60 ft and beyond

Custom widths, heights and lengths are available. These ranges are the starting point Platinum Finishing Systems (PFS) uses on the truck and fleet hub — not a catalog of stock SKUs.

CROSSFLOW TRUCK BOOTHS AT A GLANCE

Crossflow Truck Booth Applications, Airflow & Compliance

Tap a topic to open it. Tap again to close.

In a crossflow (cross-flow) truck paint booth, filtered air enters through intake filters in the product doors and travels horizontally the length of the booth to a rear exhaust wall. That front-to-rear path carries overspray away from the painter. The booth sits on a flat slab — no concrete pit and no raised floor. Comparing airflow types? See all four on the Truck & Fleet paint booths page.
Semi-trucks, buses, transit and school coaches, RVs, heavy equipment and other fleet vehicles. Crossflow is a practical choice for a long, drive-through paint booth when you want the lowest installed cost and a pit is not in the plan.
A crossflow truck booth sits on your existing slab. There is no floor pit to dig, which keeps install time and cost down compared with a full downdraft truck booth.
Every PFS truck booth is ETL listed (Intertek) for the USA and Canada. Control panels are UL 508A. Booths are built to NFPA 33. CID2 lighting and UL listed tube axial fans are standard on this line. Your local fire marshal and air district have the final say on permits.
Largest vehicle (L × W × H), drive-through or single-entry doors, building footprint and ceiling height, coatings you spray, and whether you want a heated truck paint booth, an air make-up unit, or spray and bake. Photos of the space help. Platinum Finishing Systems (PFS) will spec the booth.
TRUCK BOOTH GUIDE

Planning a Crossflow Truck Booth

A Class 8 tractor needs at least 16 ft W × 50 ft L × 14 ft H. A tractor and trailer together usually wants 16–18 ft W × 60–80 ft L. Transit, school and motor coaches typically run 14–16 ft W × 40–60 ft L × 12–14 ft H. Larger equipment can be built to 20 × 14 × 40, 24 × 16 × 50, 30 × 18 × 60 ft and beyond. Those ranges come from the PFS truck and fleet hub; custom sizes are available.

Drive-through is a common option on a crossflow truck booth for fleet shops that want vehicles to enter one end and leave the other. Single-entry still uses the same filtered-door to rear-exhaust airflow.

A crossflow truck booth sits on your slab. There is no floor pit to dig, which keeps install cost down compared with a full downdraft truck booth.

A PFS truck booth can optionally be heated with natural gas (gas-fired) or electric heat, and can run spray and bake (cure) cycles on the PFS Core Control Panel (spray, flash and cure modes). Pair the booth with a PFS air make-up unit when you need tempered replacement air; humidity control is available on the AMU.

PFS truck booths ship ETL listed (Intertek) for the USA and Canada, with UL 508A panels, and are built to NFPA 33. We supply the drawings and data your permit packet needs.

Send the largest vehicle dimensions, door type (drive-through or single-entry), shop footprint and ceiling height, the coatings you spray, and whether you want heat, an air make-up unit, or spray and bake. Photos or a simple floor sketch of the bay help us spec faster.

Tell us your vehicle dimensions.
We'll spec the booth.

Quote in 24 hours. Made in the USA with ETL listed components. Installed nationwide.

ETL listed mark
ETL & ETL-C Listed
Intertek — USA & Canada
pfs-ul508a-clean_e8efdeb8
UL 508A Certified
Industrial Control Panel Fabricator
pfs-nfpa
NFPA 33 Compliant
Spray Application Standard
EPA
EPA Compliant
Air Quality Standards
pfs-osha
OSHA Compliant
Workplace Safety Standards
Flag of the United States
Made in USA
Santa Rosa, CA

See related installs at American Event Services in Danville, IL and Mustang CAT in Hempstead, TX.

FREQUENTLY ASKED QUESTIONS

Crossflow Truck Booths — Common Questions

A crossflow truck paint booth moves filtered air horizontally down the length of the booth, from intake filters in the front doors to exhaust filters at the rear. PFS builds it as a pit-free booth for semis, buses and fleet vehicles, with a drive-through option.
No. A PFS crossflow truck booth sits on your existing concrete slab, with no pit or raised floor. That is why crossflow has the lowest installed cost of the PFS truck airflow options. Only full downdraft truck booths need a pit or a raised basement floor.
Yes. A heated crossflow truck booth is built with bridge plenums on both ends. Supply air from the air make-up unit(s) enters through the front bridge plenum and exits through the rear bridge plenum on a drive-through (pass-through) booth, or through a filtered back wall if the booth is not drive-through.
Crossflow is the most economical enclosed truck booth: air moves horizontally from front to rear on your slab. Side downdraft pulls air down from the ceiling to lower side-wall exhaust, also with no pit. Full downdraft exhausts through a grated floor and needs a pit or a raised basement.
Plan on at least 16 ft wide × 50 ft long × 14 ft high for a Class 8 tractor. If the tractor and trailer stay together, shops typically look at 16–18 ft wide and 60–80 ft long. PFS builds larger custom sizes when your vehicles need them.
Yes. Drive-through is an option on the PFS crossflow truck booth, so vehicles enter at one end and leave at the other. It is a common layout for fleet and bus work, and on a heated drive-through booth the air exits through the rear bridge plenum.
PFS truck booths can be built with natural gas (gas-fired) or electric heat. The PFS Core Control Panel runs spray, flash and cure modes, so the booth can spray and bake. A PFS air make-up unit supplies tempered, filtered air, with humidity control available.
Yes. Every PFS truck booth is ETL listed (Intertek) for the USA and Canada and built to NFPA 33. It ships with a UL 508A control panel, CID2 lighting and UL listed tube axial fans, and it is made in the USA.