A paint mix room is an enclosed, ventilated room where coatings are measured, mixed, tinted and stored, separate from the spray booth itself. A factory-built, code-compliant paint mix room that keeps flammable mixing, tinting and paint storage out of the shop and right beside your spray booth. ETL listed with UL 508A controls and built to NFPA 33. Standard sizes are 9’W × 8’H × 6–15’D, and custom sizes are available.
Product Details

PFS Standard at a Glance

Every Unit Ships Fully Certified

01

UL 508A Control Panel

Pairs with our PFS Core Control Panel — UL 508A certified with spray, flash, and cure modes. Programmable cycle timers, safety interlocks, and optional BMS integration.

02

UL Listed Tube Axial Fans

High-efficiency, UL listed tube axial fans provide consistent ventilation and exhaust airflow — keeping solvent vapors below hazardous levels at all times.

03

CID2 Lighting — 4-Tube Fixtures

Class I Division 2 inside-access four-tube light fixtures (fluorescent or LED tube compatible). Optional LED upgrade available. Uniform, shadow-free illumination for accurate color matching.

04

Fiberglass Exhaust + Tacky Intake Filters

Exhaust uses fiberglass media filters. Intake uses tacky-type filters standard. Blanket intake upgrades available for heated configurations.

05

Galvanized or Powder Coated Steel

Structural panels available in galvanized or powder coated finish. Built to NFPA 33 standards with air quality and OSHA compliance on every unit.

06

1/2 HP Motor — All Models

All standard mixing rooms ship with a 1/2 HP motor providing reliable exhaust ventilation. Sized to maintain safe vapor concentrations across all standard room depths.

07

12" Exhaust Duct — Standard

12″ exhaust duct on all models. Connects directly to your existing exhaust stack or can be routed through the roof or wall with standard HVAC fittings.

08

Personnel Door — Every Unit

Every mixing room includes one 3′ × 7′ personnel door with window for visibility and safe entry. Positive-pressure door seal keeps vapors contained.

09

We Ship Nationally

PFS mixing rooms ship to all 50 states. Factory-direct pricing, fast lead times, and dedicated project support from order through installation.

STANDARD SIZES

Typical Sizes — Custom Sizes Available

PFS Standard paint mixing room sizes (inside dimensions)
ModelW × H × DLight fixturesPersonnel doorExhaust ductApprox. weight
MR6PFS-MR6-989' × 8' × 6'13' × 7'12"1,450 lbs
MR9PFS-MR9-989' × 8' × 9'23' × 7'12"1,600 lbs
MR12PFS-MR12-989' × 8' × 12'33' × 7'12"1,800 lbs
MR15PFS-MR15-989' × 8' × 15'43' × 7'12"2,000 lbs

All standard models are 9' wide × 8' high with a 1/2 HP motor. Floor areas run 54–135 sq ft, inside the 150 sq ft limit NFPA 33 sets for mixing rooms. Custom sizes are available.

PLANNING GUIDE

Paint Mixing Room Requirements & Planning

Size, ventilation and code items to plan before you order.

NFPA 33 sets specific limits for rooms used to mix flammable and combustible liquids. They include a maximum floor area of 150 sq ft, an enclosed room with spill containment, a cap on the liquid kept inside of 2 gallons per sq ft, and mechanical ventilation of at least 1 cfm per sq ft or 150 cfm (whichever is greater) running whenever the room is in use. They also require electrical classification, automatic fire protection, and portable extinguishers. Your local fire official makes the final call, so confirm the requirements for your jurisdiction.

Start with how much paint you mix and keep on hand. The MR6 suits a single-booth shop; the MR12 and MR15 add bench space, storage racks and room for a mixing system. All four standard models stay under the 150 sq ft limit.

Mixing rooms usually sit directly beside the booth so painters walk a few steps, not across the shop. They can stand alone or integrate with the booth wall and share its exhaust.

Tube-axial fans with a 12″ exhaust duct keep air moving through filtered intake and exhaust, and the controls interlock ventilation with lighting and the shop’s fire protection.

Class I Division 2 light fixtures give accurate color matching, and the electrical inside the room is specified for its hazardous classification.

Planning the full room? Our NFPA 33 compliance guide explains how mixing rooms, booths and storage areas are reviewed together.

Ready to Configure Your Mixing Room?

Factory-direct pricing. Fast lead times. Dedicated support from order through installation.

ETL listed mark
ETL & ETL-C Listed
Intertek — USA & Canada
pfs-ul508a-clean_e8efdeb8
UL 508A Certified
Industrial Control Panel Fabricator
pfs-nfpa
NFPA 33 Compliant
Spray Application Standard
EPA logo
EPA Compliant
Air Quality Standards
pfs-osha
OSHA Compliant
Workplace Safety Standards
Flag of the United States
Made in the USA
Santa Rosa, CA
FREQUENTLY ASKED QUESTIONS

Paint Mixing Rooms — Common Questions

An industrial paint mixing room provides a dedicated, code-compliant space for paint preparation, thinning, color matching, straining, and storage of flammable liquids. Continuous cross-flow ventilation removes paint and solvent fumes, keeping the environment safe for workers and compliant with OSHA, NFPA 33, and local fire codes.

Yes. Paint mixing rooms used for the preparation and storage of flammable coatings are subject to NFPA 33 requirements. PFS mixing rooms are built to NFPA 33 standards with ETL/UL listed and certified components, OSHA compliant cross-flow ventilation, and a built-in 4-inch containment base for spill capture.

An integrated mixing room is built as part of the spray booth system — sharing a common wall with the booth and delivered as a single unit. A stand-alone mixing room is a self-contained unit that can be placed anywhere in your facility. PFS manufactures both configurations. Integrated rooms offer the advantage of single-source delivery, installation, and accountability.

Yes. PFS manufactures mixing rooms in standard and custom sizes. Standard configurations range from 8′ x 8′ to 12′ x 16′, but custom dimensions are available for non-standard facility layouts. Contact a PFS engineer for a custom quote.

PFS mixing rooms use a cross-flow ventilation system that continuously draws fresh air through intake filters on one wall and exhausts through filters on the opposite wall. This constant air exchange removes paint fumes, solvent vapors, and particulates, maintaining a safe working environment and complying with OSHA and NFPA 33 ventilation requirements.

Standard PFS mixing rooms are 9′ wide × 8′ high and 6′, 9′, 12′ or 15′ deep. Pick by the amount of paint you mix and store; all standard sizes stay under NFPA 33’s 150 sq ft limit for mixing rooms.

NFPA 33 calls for at least 1 cfm per sq ft of floor area or 150 cfm, whichever is greater, running whenever the room is in use. PFS mixing rooms are designed to meet it.

A paint mix room is where coatings are prepared: opened, measured, thinned, tinted and stored in limited amounts. A paint booth is where they are sprayed. The mix room has its own exhaust and rated lighting, with spill containment available as an option. No spraying happens inside it.
NFPA 33 sets the main rules for mixing rooms, including size limits, ventilation and fire protection. The electrical inside is classified under NEC Article 516, and OSHA and your local fire code also apply. Your fire marshal or building official makes the final call, so plan the room together with the booth permit.
Many two-component coatings contain isocyanates, which can cause asthma and skin sensitization. Doing all mixing inside a dedicated, continuously exhausted room keeps vapor away from the rest of the shop and away from the painter’s breathing zone. Ventilation lowers exposure but does not replace protection, so OSHA expects the right respirator, gloves and training whenever isocyanate coatings are handled. Check each product’s SDS.
Yes. A mix room can stand on its own or be built against the booth wall so painters walk only a few steps. Either way, it gets its own exhaust and interlocks, and it is reviewed with the booth when you apply for permits.